Microbiological Evaluation of Indoor Air Quality of State University Library
Keywords:
microbial air contamination, indoor environment, bacteria, mould fungiAbstract
The present study was aimed at evaluating the number of bacteria and mould fungi in the indoor and outdoor environment of Imo University Library. The sampling sites were located in the rooms serving the functions typical of libraries (i.e. in the Main Reading Room, Current Periodicals Reading Room, Collections Conservation Laboratory, Old Prints Storeroom, in rooms serving other (non-library) functions (i.e. main hall, cafeteria, and toilet) as well as outside the library building. The analyses reveal that the concentrations of bacterial as well as fungal aerosols estimated with the use of the impaction method ranged between 101-103 CFU·m-3, which corresponds to the concentrations normally observed in areas of this kind. Evaluation of the hygienic condition of the studied areas was based on the criteria for microbiological cleanliness in interiors submitted by the European Commission in 1993. According to this classification, the air was considered to be heavily or moderately contaminated with bacteria, while the air contamination with mould fungi was described as low or moderate. The air in the Old Prints Storeroom was considered the least contaminated with microbial aerosol
References
• Allsopp D, Seal KJ, Gaylarde ChC. Introduction to biodeterioration (2nd ed.). Cambridge University Press 2004.
• Björnsson E, Norback D, Janson C, Widstrom J, Palmgren U, Strom G, Boman G. Asthmatic symptoms and indoor levels of microorganisms and house dust mites. Clin Exp Allergy. 1995; 25: 423-431
• Dacarro C, Picco AM, Grisoli R, Redolfi M. Determination of aerial microbiological contaminations in scholastic sports environment. J Appl Microbiol. 2003; 95: 904-12.
• Commission of the European Communities (CEC): Indoor Air Quality and Its impact on Man. Report No. 12. Biological Particles in Indoor Environment, Luxemburg 1993.
• Cox CS, Waters CM. Bioaerosols handbook. Lewis Publishers, New York 1995.
• Dales RE, Zwanenburg H, Burnett R, Franklin CA. Respiratory health effects of home dampness and molds among children. Am J Epidemiol. 1991; 123: 196-203.
• Dutkiewicz J, Górny RL. Biologiczne czynniki szkodliwe dla zdrowia klasyfikacja i kryteria oceny narażenia. Med Pr. 2002; 53: 29-39.
• Górny RL. Fungal and bacterial propagules as indoor air contaminants: characteristic, release mechanisms, detection. Sosnowiec. Instit Occup Med & Environl Health Publ. 2004.
• Górny RL, Dutkiewicz J. Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries. Ann Agric Environ Med. 2002; 9: 17-23.
• Górny RL, WlazÅ‚o A, KrysiÅ„ska Traczyk E, Strzelczyk AB, Lis DO, ÅudzeÅ„ IzbiÅ„ska B, et al. Microbial contamination of water – damaged storerooms of libraries. Proc Indoor Air. 2005; 2: 1464-1468.
• Jain AK. Survey of bioaerosol in different indoor working environments in central India. Aerobiologia. 2000; 16: 221-225.
• Karwowska E. Microbiological air contamination in farming environment. Pol J Environ Stud. 2005; 14: 445-449.
• Karbowska-Berent J, Górny RL, Strzelczyk AB, Wlazło A. Airborne and dust borne microorganisms in selected Polish libraries and archives. Build Environ. 2011; 46: 1872-1879.
• Åebkowska M. Rola mikroorganizmów w niszczeniu materiałów użytkowych. In: Problemy jakoÅ›ci powietrza wewnÄ™trznego w Polsce 2003. Wydawnictwo Instytutu Ogrzewnictwa i Wentylacji Politechniki Warszawskiej, Warsaw 2004, 141-148.
• Lipiec A. Grzyby pleśniowe – ważny antygen środowiskowy. Terapia. 1997; 3: 27-30.
• Lugauskas A, Krikštaponis A. Microscopic fungi found in libraries of Vilnius and factors affecting their development. Indoor Built Environ. 2004; 13: 169-182.
• Muszyński A, Czerwińska A, Chruślińska I. Ocena jakości powietrza wewnętrznego pod względem mikrobiologicznym w pomieszczeniach dydaktycznych Wydziału Inżynierii Środowiska Politechniki Warszawskiej. Warsaw 1992.
• Newson R, Strachan D, Corden J, Millington W. Fungal and other spore counts as predictors of admission for asthma in the Trent region. Occup Environ Med. 2000; 57: 786-792.
• Pascual L, Pérez-Luz S, Yáñez MA, SantamarÃa A, Gilbert K, Salhot M, Apraiz D, Cetalán V. Bioaerosol emission from wastewater treatment plants. Aerobiol. 2003; 19: 261-270.
• Renn P, Jankun TM, Belanger K, Bracken MB, Leaderer BP. The relation between fungal propagules in indoor air and home characteristics. Allergy. 2001; 56: 419-424.
• Ross MA, Curtis L, Scheff PA, Hryhorczyk DO, Ramakrishnan V, Wadden RA, Persky VW. Association of asthma symptoms and severity with indoor bioaerosols. Allergy. 2000; 55: 705-711.
• Siersted HC, Gravesen S. Extrinsic allergic alveolitis after exposure to the yeast Endotorula rubra. Allergy. 1993; 48: 298-299.
• Wojtatowicz M, Stempniewicz R, Żarowska B, Rymowicz W, Robak M. Mikrobiologia ogólna. Wydawnictwo Uniwersytetu Przyrodniczego we Wrocławiu, Wrocław 2008.
• WlazÅ‚o A, Górny RL, ZÅ‚otkowska R, Åawniczek A, ÅudzeÅ„-IzbiÅ„ska B, Harkawy AS, Anczyk E. Narażenie pracowników na wybrane szkodliwe czynniki biologiczne w bibliotekach województwa Å›lÄ…skiego (Workers’ exposure to selected biological agents in libraries of upper Silesia) Med Pr. 2008; 59: 159-170.
Downloads
Published
Issue
Section
License
- Papers must be submitted on the understanding that they have not been published elsewhere (except in the form of an abstract or as part of a published lecture, review, or thesis) and are not currently under consideration by another journal published by any other publisher.
- It is also the authors responsibility to ensure that the articles emanating from a particular source are submitted with the necessary approval.
- The authors warrant that the paper is original and that he/she is the author of the paper, except for material that is clearly identified as to its original source, with permission notices from the copyright owners where required.
- The authors ensure that all the references carefully and they are accurate in the text as well as in the list of references (and vice versa).
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Attribution-NonCommercial 4.0 International that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
- The journal/publisher is not responsible for subsequent uses of the work. It is the author's responsibility to bring an infringement action if so desired by the author.