Performance evaluation can provide information on how far an earthquake will affect building structure. This is important for evaluating the seismic behavior of post-yield building structures. The purposes of this study were to evaluate the story shear force that occurred, evaluate the distribution of plastic hinge, and evaluate the high rise building structure performance level during an earthquake. This research was conducted using static nonlinear analysis and calculated using capacity spectrum method. The plastic hinges that formed in the global-x and global-y direction were 1 and 52. Several elements are in collapse prevention level. This shows the element behavior and performance on performance point were not good. The performance level of building structure based on the calculation was damage control. The results show that the building structure was not efficient enough, because for a return period of 2500 years based on SNI 1726-2012, building performance was expected at damage control level.

Author Biography

Rifqi Fauzan, Bogor Agricultural University

Civil and Environmental Engginering

References

Dong P, Guo H, “A Framework for automated assessment of post-earthquake building damage using geospatial dataâ€, International Journal of Remote Sensing, vol. 33, no. 1, pp.81-100, 2012.

Mamesah H Y, “Analisis Pushover pada Bangunan dengan Soft First Storyâ€, International Journal of Remote Sensing, vol. 33, no. 1, pp.81-100, 2012.

Dya A F C, Oretaa A W C, “Seismic Vulnerability Assessment of Soft Story Irregular Buildings using Pushover Analysisâ€, Proceeding of The 5th International Conference of Euro Asia Civil Engineering Forum (EACEF-5), pp. 925-932, 2012.

Nurhadi M, Budi A S, Supardi, “Evaluasi Kinerja Gaya Gempa pada Struktur Gedung Bertingkat dengan Analisis Pushover berdasar pada Drift dan Displacement menggunakan Software Etabs (Studi Kasus : Hotel di Wilayah Karanganyar)â€, e-Jurnal Matriks Teknik Sipil, vol. 2, no. 2, pp.123-130, 2014.

Dewobroto W, “Evaluasi Kinerja Bangunan Baja Taha Gempa dengan SAP2000â€, Computers and Structurs, vol. 8, no. 3, pp.2483-2943, 2002.

Hasan R, Xu L, Grierson D E, “Push-over Analysis for Performance Based Seismic Designâ€, Jurnal Teknik Sipil, vol. 3, no. 1, pp.7-24, 2006.

Zou X K, Cham C M, “Optimal Seismic Performance-Based Design of Reinforced Concrete Buildings using Nonlinear Pushover Analysisâ€, Engineering Structure, vol. 27, no. 8, pp.1289-1302, 2005.

Tso W K, Moghadam A S, “Pushover Procedure for Seismic Analysis of Buildingsâ€, Progress in Structural Engineering and Materials, vol. 1, no. 3, pp.337-344, 1998.

Kovela P R, Balaji K V G D, Raju G S S S V, Rao S S, “Nonlinear Pushover Analysis for Performance Based Engineering Design - A Reviewâ€, International Journal for Research in Applied Science & Engineering Technology, vol. 5, no. 3, pp.1293-1300, 2017.

Mahdi T, Gharraie S, “Plan Irregular RC Frames: Comparison of Pushover with Nonlinear Dynamic Analysisâ€, Asian Journal of Civil Engineering (Building and Housing), vol. 12, no. 6, pp.213-224, 2011.

Khan R A, “Performance Based Seismic Design of Reinforced Concrete Buildingâ€, International Journal of Innovative Research in Science, Engineering and Technology, vol. 3, no. 6, pp.13495-13506, 2014.

Krawinkler H, Seneviratna G D P K, “. Pros and Cons of Pushover Analysis of Seismic Performance Evaluation†Engineering Structures, vol. 20, no. 4-6, pp.452-464, 1998.

Pranata Y A, “Evaluasi Kinerja Gedung Beton Bertulang Tahan Gempa dengan Pushover Analysis (Sesuai ATC-40, FEMA 356, dan FEMA 440)â€, Jurnal Teknik Sipil, vol. 3, no. 1, pp.41-52, 2006.

Applied Technology Council. ATC 40, Seismic Evaluation an Retrofit of Concrete Buildings (ATC), USA, 1996

Badan Standardisasi Nasional. SNI 1726-2012, Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung (BSN). INA, 2012

Badan Standardisasi Nasional. SNI 1727-2013, Beban Minimum untuk Perancangan Bangunan Gedung dan Struktur Lain (BSN). INA, 2013

Departemen Pekerjaan Umum. PPURG, Pedoman Perencanaan Pembebanan untuk Rumah dan Gedung (Yayasan Badan Penerbit PU). INA, 1987

Badan Standardisasi Nasional. SNI 1726-2002, Standar Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung (BSN). INA, 2012

Oh S H, Jeon J, “. A Study on Optimum Distribution of Story Shear Force Coefficient for Seismic Design of Multi-story Structure†International Journal of High-Rise Buildings, vol. 3, no. 2, pp.121-145, 1994.

Budiono B, Dewi N T H, Kristalya M, Manik S L C, Ong E H K, Contoh Desain Bangunan Tahan Gempa dengan Sistem Rangka Pemikul Momen Khusus dan Sistem Dinding Struktur Khusus di Jakarta (Penerbit ITB), INA, 2017

Downloads

Published

2019-03-18

How to Cite

Fauzan, R., Basa, E., & Sapei, A. (2019). Nonlinear Performance Evaluation of High Rise Building Structure. Asian Journal of Applied Sciences, 7(1). https://doi.org/10.24203/ajas.v7i1.5740